info@logosmeter.com| Technical parameters | |||||
| Model | Accuracy | Reference voltage (V) | Current specifications (A) | Starting current (A) | Insulation performance |
| LEM061XX | Class 1 | 3×400 3×230/400 |
CT/5 10(60) 20(120) |
0.01 0.04 0.08 |
AC voltage 4kV for 1 minute, 1.2/50us waveform impulse voltage 6kV. |

| Wiring diagram -1 (type 16B) | |||
![]() |
Terminals | Note | |
| 1 | Inlet on Phase L1 | ||
| 3 | Outlet on Phase L1 | ||
| 4 | Inlet on Phase L2 | ||
| 6 | Outlet on Phase L2 | ||
| 7 | Inlet on Phase L3 | ||
| 9 | Outlet on Phase L3 | ||
| 10 | Inlet neutral wire | ||
| 11 | Outlet neutral wire | ||
| 20and 21 | Passive energy impulse output port | ||
| Wiring diagram -2 (type 13B) | ||||
![]() |
Terminals | Note | ||
| 1 | Inlet on Phase L1 | |||
| 3 | Outlet on Phase L1 | |||
| 4 | Inlet on Phase L2 | |||
| 6 | Outlet on Phase L2 | |||
| 7 | Inlet on Phase L3 | |||
| 9 | Outlet on Phase L3 | |||
| 10 | No use | |||
| 11 | No use | |||
| 20and 21 | Passive energy impulse output port | |||
| Wiring diagram -3 (type 48B) | ||||
![]() |
Terminals | Note | ||
| 1 | Inlet of CT on Phase L1 | |||
| 3 | Outlet of CT on Phase L1 | |||
| 4 | Inlet of CT on Phase L2 | |||
| 6 | Outlet of CT on Phase L2 | |||
| 7 | Inlet of CT on Phase L3 | |||
| 9 | Outlet of CT on Phase L3 | |||
| 2 | L1 Phase line | |||
| 5 | L2 Phase line | |||
| 8 | L3 Phase line | |||
| 10 | Neutral line | |||
| 20and 21 | Passive energy impulse output port | |||
| Wiring diagram -4 (type 5B) | |||
![]() |
Terminals | Note | |
| 1 | Inlet of CT on Phase L1 | ||
| 3 | Outlet of CT on Phase L1 | ||
| 4 | No use | ||
| 6 | No use | ||
| 7 | Inlet of CT on Phase L3 | ||
| 9 | Outlet of CT on Phase L3 | ||
| 2 | L1 Phase line | ||
| 5 | L2 Phase line | ||
| 8 | L3 Phase line | ||
| 10 | No use | ||
| 20and 21 | Passive energy impulse output port | ||
| Product configuration table | ||||||||||||
| Configuration Options | Configuration Code | |||||||||||
| AG | AI | AJ | AK | AL | JK | JL | MK | ML | MI | MJ | ||
| 6 digits (999999kWh) step motor impulse register | ● | ● | ● | ● | ● | |||||||
| 6+1 digits (999999.1kWh) LCD | ● | ● | ● | ● | ||||||||
| 5+2 digits or 7 integers, automatically depended on the setting CT rate | ● | ● | ||||||||||
| LCD display to read the meter when power is cut | ● | ● | ● | ● | ||||||||
| Short terminal cover | ● | ● | ● | ● | ● | |||||||
| Extended terminal cover | ● | ● | ● | ● | ● | ● | ||||||
| Outer and mounting dimension - Picture 1 | ● | ● | ● | ● | ● | |||||||
| Outer and mounting dimension - Picture 2 | ● | ● | ● | ● | ● | ● | ||||||
| Direct connection | ● | ● | ● | ● | ● | ● | ● | |||||
| CT connection | ● | ● | ● | ● | ||||||||
| Direct reading and can set 27 kinds of CT rates | ● | ● | ||||||||||
| Three phase four wire, Type 16B (Wiring diagram - 1) | ● | ● | ● | ● | ||||||||
| Three phase three wire, Type 13B (Wiring diagram - 2) | ● | ● | ● | |||||||||
| Three phase four wire, Type 48B (Wiring diagram - 3) | ● | |||||||||||
| Three phase three wire, Type 5B (Wiring diagram - 4) | ● | |||||||||||
| Three phase four wire, Type 48B (Wiring diagram - 5) | ● | |||||||||||
| Three phase three wire, Type 5B (Wiring diagram - 6) | ● | |||||||||||