Technical parameters | |||||
Model | Accuracy | Reference voltage (V) | Current specifications (A) | Starting current (A) | Insulation performance |
LEM061XX | Class 1 | 3×400 3×230/400 |
CT/5 10(60) 20(120) |
0.01 0.04 0.08 |
AC voltage 4kV for 1 minute, 1.2/50us waveform impulse voltage 6kV. |
Wiring diagram -1 (type 16B) | |||
|
Terminals | Note | |
1 | Inlet on Phase L1 | ||
3 | Outlet on Phase L1 | ||
4 | Inlet on Phase L2 | ||
6 | Outlet on Phase L2 | ||
7 | Inlet on Phase L3 | ||
9 | Outlet on Phase L3 | ||
10 | Inlet neutral wire | ||
11 | Outlet neutral wire | ||
20and 21 | Passive energy impulse output port |
Wiring diagram -2 (type 13B) | ||||
|
Terminals | Note | ||
1 | Inlet on Phase L1 | |||
3 | Outlet on Phase L1 | |||
4 | Inlet on Phase L2 | |||
6 | Outlet on Phase L2 | |||
7 | Inlet on Phase L3 | |||
9 | Outlet on Phase L3 | |||
10 | No use | |||
11 | No use | |||
20and 21 | Passive energy impulse output port |
Wiring diagram -3 (type 48B) | ||||
|
Terminals | Note | ||
1 | Inlet of CT on Phase L1 | |||
3 | Outlet of CT on Phase L1 | |||
4 | Inlet of CT on Phase L2 | |||
6 | Outlet of CT on Phase L2 | |||
7 | Inlet of CT on Phase L3 | |||
9 | Outlet of CT on Phase L3 | |||
2 | L1 Phase line | |||
5 | L2 Phase line | |||
8 | L3 Phase line | |||
10 | Neutral line | |||
20and 21 | Passive energy impulse output port |
Wiring diagram -4 (type 5B) | |||
Terminals | Note | ||
1 | Inlet of CT on Phase L1 | ||
3 | Outlet of CT on Phase L1 | ||
4 | No use | ||
6 | No use | ||
7 | Inlet of CT on Phase L3 | ||
9 | Outlet of CT on Phase L3 | ||
2 | L1 Phase line | ||
5 | L2 Phase line | ||
8 | L3 Phase line | ||
10 | No use | ||
20and 21 | Passive energy impulse output port |
Product configuration table | ||||||||||||
Configuration Options | Configuration Code | |||||||||||
AG | AI | AJ | AK | AL | JK | JL | MK | ML | MI | MJ | ||
6 digits (999999kWh) step motor impulse register | ● | ● | ● | ● | ● | |||||||
6+1 digits (999999.1kWh) LCD | ● | ● | ● | ● | ||||||||
5+2 digits or 7 integers, automatically depended on the setting CT rate | ● | ● | ||||||||||
LCD display to read the meter when power is cut | ● | ● | ● | ● | ||||||||
Short terminal cover | ● | ● | ● | ● | ● | |||||||
Extended terminal cover | ● | ● | ● | ● | ● | ● | ||||||
Outer and mounting dimension - Picture 1 | ● | ● | ● | ● | ● | |||||||
Outer and mounting dimension - Picture 2 | ● | ● | ● | ● | ● | ● | ||||||
Direct connection | ● | ● | ● | ● | ● | ● | ● | |||||
CT connection | ● | ● | ● | ● | ||||||||
Direct reading and can set 27 kinds of CT rates | ● | ● | ||||||||||
Three phase four wire, Type 16B (Wiring diagram - 1) | ● | ● | ● | ● | ||||||||
Three phase three wire, Type 13B (Wiring diagram - 2) | ● | ● | ● | |||||||||
Three phase four wire, Type 48B (Wiring diagram - 3) | ● | |||||||||||
Three phase three wire, Type 5B (Wiring diagram - 4) | ● | |||||||||||
Three phase four wire, Type 48B (Wiring diagram - 5) | ● | |||||||||||
Three phase three wire, Type 5B (Wiring diagram - 6) | ● |