>
Technical parameters | |||||
Model | Accuracy | Reference voltage (V) | Current specifications (A) | Starting current (A) | Insulation performance |
LEM081XX | Class 2 | 127 or 230 | 5(20) 10(40) 15(60) 20(80) 30(100) |
0.025 0.050 0.075 0.100 0.150 |
AC voltage 4kV for 1 minute, 1.2/50us waveform impulse voltage 6kV. |
Wiring diagram -1 (type 16A) | |||
|
Terminal | Note | |
1S | Inlet on Phase L1 | ||
2S | Inlet on Phase L2 | ||
3S | Inlet on Phase L3 | ||
0S | Inlet neutral wire | ||
1L | Outlet on Phase L1 | ||
2L | Outlet on Phase L2 | ||
3L | Outlet on Phase L3 | ||
0L | Outlet neutral wire |
Wiring diagram -2 (type 16B) | |||
Terminal | Note | ||
1 | Inlet on Phase L1 | ||
3 | Outlet on Phase L1 | ||
4 | Inlet on Phase L2 | ||
6 | Outlet on Phase L2 | ||
7 | Inlet on Phase L3 | ||
9 | Outlet on Phase L3 | ||
10 | Inlet neutral wire | ||
11 | Outlet neutral wire |
Wiring diagram -3 (type 48B) | |||
Terminal | Note | ||
1 | Inlet CT on Phase L1 | ||
3 | Outlet CT on Phase L1 | ||
4 | Inlet CT on Phase L2 | ||
6 | Outlet CT on Phase L2 | ||
7 | Inlet CT on Phase L3 | ||
9 | Outlet CT on Phase L3 | ||
2 | L1 Phase line | ||
5 | L2 Phase line | ||
8 | L3 Phase line | ||
10 | Neutral line |
Product configuration table | ||||||||||||
Configuration Options | Configuration Code | |||||||||||
QD | QP | PP | PQ | RP | RQ | UP | UQ | TP | TQ | |||
Meter cover material-good Bakelite | ● | ● | ● | |||||||||
Meter cover material-transparent anti-ultraviolet PC | ● | ● | ||||||||||
Meter cover material-top quality aluminium plate | ● | ● | ||||||||||
Meter cover material-ABS engineering plastic | ● | ● | ● | ● | ||||||||
Meter bottom material-good Bakelite | ● | ● | ● | ● | ● | |||||||
Meter bottom material-top quality steel plate | ● | ● | ● | ● | ● | ● | ||||||
Terminal cover material-good Bakelite | ● | ● | ● | |||||||||
Terminal cover material-black PC | ● | ● | ||||||||||
Terminal cover material-top quality steel plate | ● | ● | ● | ● | ||||||||
Terminal cover material-ABS engineering plastic | ● | ● | ||||||||||
Terminal block material-good Bakelite | ● | ● | ● | ● | ● | ● | ● | |||||
Extended terminal cover | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||
Short terminal cover | ● | ● | ||||||||||
Outer and mounting dimension - Picture 1 | ● | |||||||||||
Outer and mounting dimension - Picture 2 | ● | ● | ● | ● | ● | ● | ||||||
Outer and mounting dimension - Picture 3 | ● | ● | ||||||||||
Outer and mounting dimension - Picture 4 | ● | ● | ||||||||||
Three Phase four wire, Direct connection, Wiring diagram -1 (type 16A) | ● | |||||||||||
Three Phase four wire, Direct connection, Wiring diagram -2 (type 16B) | ● | ● | ● | ● | ● | |||||||
Three Phase four wire, CT connection, Wiring diagram -3 (type 48B) | ● | ● | ● | ● | ● |